Have done a bit of debugging here over the past few days regarding this issue, and come up with a fix.
I sent Captain Jack a message this morning to test this and he's confirmed it works on his HD51, it's working on some other E2 boxes here,
it seems something was changed in the OA E2 image that breaks something to do with Diseqc commands.
Symptoms are, failing to lock/tune after moving the dish with a black screen, changing satellites and back sometimes solves it.
Motor failing to move etc.
FTP in to box...
go to etc/enigma2/settings
Looking at your screenshots you are showing lnb.1 not lnb.65, so looks like screenshot isn't showing the tuner with the motor on?
Change the line with the correct lnb number for the motor
Also nims number will be 0 or 1 (tuner 1 or 2) depending on tuner. So anywhere in the list below you see a nims number, check its the correct tuner the motor is on and edit that line.
Find a line similar to this, if motor is on "Advanced"
config.Nims.0.dvbs.advanced.lnb.65.powerMeasurement=false (just change false to true, only the line with correct nims and lnb for the motor)
If you are decide to use the "Positioner Option" under "Simple" instead of "Advanced" you change this line.
config.Nims.0.dvbs.powerMeasurement=false (just change false to true)
Further things to try, but try the power setting first.
I've changed these figures so the box doesn't try to scan/tune before the dish hits the bird, these are for a STAB-HH100
config.Nims.0.dvbs.advanced.lnb.65.turningspeedH=1.8
config.Nims.0.dvbs.advanced.lnb.65.turningspeedV=1.2
and under simple:
config.Nims.0.dvbs.turningspeedH=1.8
config.Nims.0.dvbs.turningspeedV=1.2
I sent Captain Jack a message this morning to test this and he's confirmed it works on his HD51, it's working on some other E2 boxes here,
it seems something was changed in the OA E2 image that breaks something to do with Diseqc commands.
Symptoms are, failing to lock/tune after moving the dish with a black screen, changing satellites and back sometimes solves it.
Motor failing to move etc.
FTP in to box...
go to etc/enigma2/settings
Looking at your screenshots you are showing lnb.1 not lnb.65, so looks like screenshot isn't showing the tuner with the motor on?
Change the line with the correct lnb number for the motor
Also nims number will be 0 or 1 (tuner 1 or 2) depending on tuner. So anywhere in the list below you see a nims number, check its the correct tuner the motor is on and edit that line.
Find a line similar to this, if motor is on "Advanced"
config.Nims.0.dvbs.advanced.lnb.65.powerMeasurement=false (just change false to true, only the line with correct nims and lnb for the motor)
If you are decide to use the "Positioner Option" under "Simple" instead of "Advanced" you change this line.
config.Nims.0.dvbs.powerMeasurement=false (just change false to true)
Further things to try, but try the power setting first.
I've changed these figures so the box doesn't try to scan/tune before the dish hits the bird, these are for a STAB-HH100
config.Nims.0.dvbs.advanced.lnb.65.turningspeedH=1.8
config.Nims.0.dvbs.advanced.lnb.65.turningspeedV=1.2
and under simple:
config.Nims.0.dvbs.turningspeedH=1.8
config.Nims.0.dvbs.turningspeedV=1.2